View Single Post
Old 05-28-2013, 07:35 AM   #11
5/0
Eels
iTrader: (0)
 
5/0's Avatar
 
Join Date: Jul 2004
Location: Cape Cod,MA.
Posts: 3,334
American H20 co. Is a sub division of A.O.Smith,
The flame guard series have 2 or three black vinyl screens that slide/ friction clip that are about 1.5" in height and 12-14" in length these fit into the bottom perimeter of the tank.there perpouse is to collect the dust from the surrounding area.
Salthart has a good point,about the valve being faulty,
If the thermocouple is fine and sending a milli volts signal to the gas valve then the ECO Emergency Cut Off us failing.
This would take about five mins. to diagnose with a couple of simple tools, voltmeter 3/8",1/2" 7/16" box wrench.
Posted from my iPhone/Mobile device
5/0 is offline   Reply With Quote