Sump installation

Need to get this done.What trade does this come under,plumbing?I'm a painter...I can make stuff look awesome,but installation is another thing.

I get the basic idea of how this works.I need a 12"-14" diameter hole that is a min. of 25" deep that the pump goes in.After that the instructions ain't so clear.They seem very specific but I don't fully understand some of it.

I want this done right and I'm not confident that I can do this without screwing up the warranty on the pump.

Some feedback from people in the trades would be much appreciated.
basswipe is offline   Reply With Quote
Old 04-04-2010, 02:05 PM   #2
spence
Registered User
iTrader: (0)
 
spence's Avatar
 
Join Date: Nov 2003
Location: RI
Posts: 21,464
You may want to describe the problem area and proposed installation.

I'm adding another sump this year. Determined the water table is just a few inches lower than my basement slab in a spot!

-spence
spence is offline   Reply With Quote
Old 04-04-2010, 02:29 PM   #3
striperman36
Old Guy
iTrader: (0)
 
striperman36's Avatar
 
Join Date: Oct 2004
Location: Mansfield, MA
Posts: 8,760
seems to be an issue all over aquidneck, have many at work in similar situations.
striperman36 is offline   Reply With Quote
Old 04-04-2010, 02:32 PM   #4
tattoobob
Soggy Bottom Boy
iTrader: (0)
 
tattoobob's Avatar
 
Join Date: Jan 2004
Location: Billerica, Ma.
Posts: 7,260
You want to make a hole in the floor 24 inches down or the depht of a 5 gallon bucket

then take a 5 gallon bucket drill alot of 1/4 to 1/2 inch holes in it

then line the bottom of the hole in the floor with crushed stone,

set the bucket in the hole you dug and level it

surround the bucket sides with the crushed stone and cement in place level with the floor

Surfcasting Full Throttle

Don't judge me Monkey

Recreational Surfcaster 99.9% C&R
tattoobob is offline   Reply With Quote
Old 04-04-2010, 02:39 PM   #5
Nebe
Registered User
iTrader: (0)
 
Nebe's Avatar
 
Join Date: Sep 2003
Location: Libtardia
Posts: 21,692
Just my opinion, but blowing a hole in your floor to DRAIN water is asking for water to come into your basement- you hear people say "my pump couldnt keep up with the water" That is because the water table has risen above your floor level and it will just blast up through the hole- If I was going to put a pump in a basement, Id blow a larger hole than needed, slide a sono tube in the hole and pour cement around the outside of the tube up to the floor level. Then remove the tube, and pour a floor for the pump. From there, Id seal ever crack in your basement with what ever the best product for that use is..
Nebe is offline   Reply With Quote
Old 04-04-2010, 02:54 PM   #6
nightfighter
Seldom Seen
iTrader: (0)
 
nightfighter's Avatar
 
Join Date: May 2001
Posts: 10,543
Sump Pump Basin | Sump Pump Pit | Liners and Basins

I've used a couple of the models shown on installations for clients, but Bob's suggestion works just as well, provided the pump doesn't call for a wider diameter hole.

“Americans have the right and advantage of being armed, unlike the people of other countries, whose leaders are afraid to trust them with arms.” – James Madison.
nightfighter is offline   Reply With Quote
Old 04-04-2010, 03:30 PM   #7
basswipe
Registered User
iTrader: (0)
 
basswipe's Avatar
 
Join Date: Feb 2004
Location: RI
Posts: 5,705
One of my major issues is cutting into the slab.I have access to a core-bore drill but that thing is a little intimidating.

The other thing is this mish-mash of PVC piping,the height of the check-valve and adaptors from that to the actual outflow tubing.

I thought it was as simple as a hole in the ground,put pump,attach hose and be done.Apparently this isn't the case.

Last edited by basswipe; 04-04-2010 at 05:09 PM..
basswipe is offline   Reply With Quote
Old 04-04-2010, 03:57 PM   #8
striperman36
Old Guy
iTrader: (0)
 
striperman36's Avatar
 
Join Date: Oct 2004
Location: Mansfield, MA
Posts: 8,760
Boat fishing is easy. Every thing else you're screwed
striperman36 is offline   Reply With Quote
Old 04-04-2010, 06:40 PM   #9
Saltheart
Registered User
iTrader: (1)
 
Saltheart's Avatar
 
Join Date: May 2000
Location: Cumberland,RI
Posts: 8,555
I have a sump that at one point never ran. I was bone dry. Then new contruction of an industrial park where they routed all its run off towards my neighborhood resulted in the need to pum in the wet seasons. Its bone dry mid summer and while not dry , it doesn't run much when eventhing is frozen.


Key elements are locating the pump itself if its a diaphram submersible or the float ball if its that style , at the correct hight. You want it to run before it gets up to floor level but you don't need to pump forever trying to lower the whole watertable by 5 feet.

The check valve is tough and if possible I would try not to use one. As long as the pump doesn't cycle do to the backflow from the vertical pipe , you don't need or want a check valve IMO. If the check vale is a simple one it could get stuck and then you flood. That means you may need a spring loaded one and when the spring gets old or crappy the valve can again get stuck.


I use a hole just about 18 inchhes deep with wshed stone the size of say big starwberries. I use a little Giant bronxe submersible pump. It has a diaphram switch and so I use the stones to get the right height so that the pump turns on when the water is abot 4 inches below the floor. Lost and lots of days I do not have to pump because the water is just 5 or 6 inches below the floor. The pump is very expensive , like $450 but its a great pump and will last 35 years. Even then its probably the diaphram switch that will go , not the bronze pump elements. The diaphram switch can be rebuilt even after 35 years with a kit. The pump has a lot of capoacity so I never face the situation of "the pump can't keep up". In fact I think it pumps so much water there are times I think its cycling on and off too much because my hole is too small in diameter , not too deep.

Anyway , you may want to talk to some more people because a deep hole and check valves , etc is almost exactly the opposite of what you need in many cases.

I don't understand Ebens post at all. I'm not saying he's wrong , I just don't understand what he means the way he describes cementing in the hole.

Saltheart
Custom Crafted Rods by Saltheart
Saltheart is offline   Reply With Quote
Old 04-05-2010, 10:28 AM   #10
MakoMike
Registered User
iTrader: (0)
 
MakoMike's Avatar
 
Join Date: Feb 2003
Location: Newtown, CT
Posts: 5,659
Installation specifics also depend on whether or not you have perimeter (French) drains around the basement. Most systems do use a check valve installed about 3 feet above the pump. Without the check valve you can run into a situation where the drain from the vertical pipe is enough to turn the pump back on, then the pump will just go on and off ad infinitum.

****MakoMike****

Http://www.Makomania.net

Official S-B Sponsor
MakoMike is offline   Reply With Quote
Old 04-05-2010, 09:28 PM   #11
bostonharbor
Registered User
 
Join Date: Mar 2006
Posts: 69
Blog Entries: 1
sump pump

saltheart is giving good advice.I have put in a lot pumps.You must drain the water before it seeps up through the floor.However,You do not want to pump the Town.Or maybe that would be a good project.
:
bostonharbor is offline   Reply With Quote
Old 04-10-2010, 03:45 PM   #12
basswipe
Registered User
iTrader: (0)
 
basswipe's Avatar
 
Join Date: Feb 2004
Location: RI
Posts: 5,705
Quote:
Originally Posted by tattoobob View Post
You want to make a hole in the floor 24 inches down or the depht of a 5 gallon bucket

then take a 5 gallon bucket drill alot of 1/4 to 1/2 inch holes in it

then line the bottom of the hole in the floor with crushed stone,

set the bucket in the hole you dug and level it

surround the bucket sides with the crushed stone and cement in place level with the floor
Slab has been opened and hole dug.

Got a question about the holes to be drilled in the bucket.Should I drill holes throughout the entire depth of the bucket(including bottom)?

The reason I ask is that if water gets into the basement from means other than the ground would not the holes be self-defeating?Its my thought that maybe holes should only be drilled in the upper portion of the bucket to cover the ground water issue?

I'm no expert so that is why I am asking many questions!

Thanks.
basswipe is offline   Reply With Quote
Old 04-10-2010, 04:02 PM   #13
tattoobob
Soggy Bottom Boy
iTrader: (0)
 
tattoobob's Avatar
 
Join Date: Jan 2004
Location: Billerica, Ma.
Posts: 7,260
I drill holes in the bottom and the sides the whole bucket, If you do get water say from a leaking water heater you can sweep or squeegee the water into the the bucket and the water will drain into the ground with out turning your pump on, if the water table is low enough

Surfcasting Full Throttle

Don't judge me Monkey

Recreational Surfcaster 99.9% C&R
tattoobob is offline   Reply With Quote
Old 04-10-2010, 04:06 PM   #14
Nebe
Registered User
iTrader: (0)
 
Nebe's Avatar
 
Join Date: Sep 2003
Location: Libtardia
Posts: 21,692
Quote:
Originally Posted by tattoobob View Post
I drill holes in the bottom and the sides the whole bucket, If you do get water say from a leaking water heater you can sweep or squeegee the water into the the bucket and the water will drain into the ground with out turning your pump on, if the water table is low enough
BUT.... if the water table is high, and the water comes in that hole faster than the pump will pump, the pump is completely useless....
Nebe is offline   Reply With Quote
Old 04-10-2010, 04:11 PM   #15
basswipe
Registered User
iTrader: (0)
 
basswipe's Avatar
 
Join Date: Feb 2004
Location: RI
Posts: 5,705
Quote:
Originally Posted by tattoobob View Post
I drill holes in the bottom and the sides the whole bucket, If you do get water say from a leaking water heater you can sweep or squeegee the water into the the bucket and the water will drain into the ground with out turning your pump on, if the water table is low enough
Thanks Bob.Just needed some clarity on that point.
basswipe is offline   Reply With Quote
Old 04-10-2010, 04:16 PM   #16
basswipe
Registered User
iTrader: (0)
 
basswipe's Avatar
 
Join Date: Feb 2004
Location: RI
Posts: 5,705
Quote:
Originally Posted by Nebe View Post
BUT.... if the water table is high, and the water comes in that hole faster than the pump will pump, the pump is completely useless....
I didn't screw around,I went with a 3/4hp pump.I tested it in a unused 55gal. fish tank.It emptied the tank faster than I could gun down a UFO!
basswipe is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 05:11 PM.


Powered by vBulletin. Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Please use all necessary and proper safety precautions. STAY SAFE Striper Talk Forums
Copyright 1998-20012 Striped-Bass.com